Thứ Sáu, 28 tháng 6, 2013

NEGELE sensor Viet Nam Distributor - HPQ Tech Vietnam Co.,Ltd nhà phân phối chính thức cảm biến Negele tại Việt Nam

NEGELE Viet Nam Distributor
HPQ tự hào là đại lý phân phối độc quyền cảm biến NEGELE tại Việt Nam

Nguyễn Hoài Quyết
DĐ: 0938 400 412
Email: hoaiquyet@hpqtech.com / nguyenhoaiquyet@gmail.com
Company name: HPQ Co.,Ltd
Address: 519/10 Road No.10, Ward 8, Go Vap District, HCMC, Viet Nam.
http://www.hpqtech.com
Tel: 08 6295 8401
Fax: 08 6295 8402

NEGELE - Hygienic Sensors- HPQ Tech Vietnam Co.,Ltd
Level detection and flow monitoring in the pharmaceutical industry
NEGELE sensors for PHARMadapt EPA are based on measure
principles, which have proved oneself thousandfold.

A further miniaturization and the using of pharmagrade
materials made the application in smallest tubes possible.
Advantages:
• Approved measurement principles for point level and temperature
• Also for mediums without electrical conductivity (WFI)
• Point Level: from DN 10 possible (EPA-8, EPA-18)
• Temperature: from DN 10 (EPA-8, EPA-18)
• Using only FDA- listed materials
• Sensor-fixing with usual Clamp-tension-ring
• Possibility to fix TAG-number plate out of SS
Temperature transmitters - HPQ Tech Vietnam Co.,Ltd
NEGELE temperature measurement includes also converters
and transmitters. Maybe integrated in the connecting head of the temperature sensor or as an external transmitter mounted in a cabinet. Compact design, high precision and simple operation are labeled by the NEGELE converters.

The temperature measurement is transformed in an electrical
signal 0-20 mA, 4-20 mA or 0-10 VDC.

Converters for Fieldsystems HART and Profi BUS are available

Advantage head transmitters:
• Reduced electrical wiring
• High interference resistance
• External converter not nessesary
• Programmable transmitter by PC
• (4-20 mA, 2-point control)
• Transmitters with ProfiBUS and HART protocol
• Optionally illuminated Liquid Crystal Display LCD
Hydrostatic Level Measurement - HPQ Tech Vietnam Co.,Ltd
NEGELE pressure sensors with ceramic measuring cells are perfect for taking high-precision hydrostatic level measurements
and differential pressure measurements.

There are also sensors for extremely wet environments with hydraulically coupled and hermetically closed stainless
steel double membranes.

That makes condensation problems a thing of the past. Only FDA-compliant materials come into contact with product.

Advantages: - HPQ Tech Vietnam Co.,Ltd
Sensor with Ceramic measuring cell
• Accurate, rugged
• High overload protection closed
• Measuring cells not oil-filled
• Stainless steel 1.4404/316L
• IP69K
• CIP-/SIP capable 140°C / 30 min

Sensor with SS membrane
• Accurate, hermetically
• Ideal for extremely wet environments
• Stainless steel 1.4404/316L
• IP69K
• CIP-/SIP capable 140°C / 30 min
Potentiometric Level Measurement - HPQ Tech Vietnam Co.,Ltd
With NEGELE sensors, you can continuously measure the levels in vessels that are 2.5 m and smaller consistently, cost-effectively and easily.

You can choose from a wide product range containing various
models and probe lengths for your specific needs. Our sensors can measure all liquid media with a minimum conductivity
of 1 μS/cm.

Advantages: - HPQ Tech Vietnam Co.,Ltd
• Highly dynamic measurements, ideal for balance and filter tanks
• Perfect for closed loop level controls
• Extremely accurate – even at low levels
• Two-rod probe also available for non-metallic tanks
• Probe rod length can be specified to within one millimeter
• Can be installed from above or below
• Not sensitive to adhesion of product
• Ideal for pressurized tanks as an alternative to differential pressure measurement
• Materials: 1.4404/316L (316 L), PEEK
• Suitable for pharma & food
• CIP-/SIP capable 140°C / 30 min.
Conductive Limit Switches - HPQ Tech Vietnam Co.,Ltd
The value model for watery and conductive media

Advantages:
• Single-rod and multiple-rod probes
• Fast response time and adjustable sensitivity
• Probe rods can be shortened and bent
• Electrodes available with or without PFA coating
• Integrated level transmitter
• CIP-/SIP capable
• Models approved under the Federal Water Regulation (WHG)

Process Adaptation - HPQ Tech Vietnam Co.,Ltd
All NEGELE limit switches can be used in combination with both conventional process adaptation methods and the NEGELE CLEANadapt system.

CLEANadapt is easy to clean.
Its cleaning capabilities have been accredited in various international certificates (3A, EHEDG, FDA).

Fast - reliable - cost-effective74
Pressure gauge - HPQ Tech Vietnam Co.,Ltd
NEGELE Pressure Gauges are optimized for hygienic applications. You can directly adapt them or use it with the CLEANadapt system to any established process connection. Available in 63 mm and 90 mm diameters.

Only FDA-compliant materials come into contact with the product.

Advantages:
• integrated, hygenic-compatible process connection
• IP66 closed housing for optimal cleaning
• Sensors made entirely out of stainless steel • All the product contact surfaces and the fill fl uid are FDA-compliant
• Autoclavable model available
• Also available glycerine-filled
• Product is certified by 3A
• CIP-/SIP capable 140°C / 30 min.
Electrical Process Pressure Sensor - HPQ Tech Vietnam Co.,Ltd
The pressure sensors with highly overload-proof ceramic measuring cells are ideal for taking precise pressure measurements
in gases and fluids.

Advantages:
• Rugged, high-precision measuring cell
• Highly resistant to pressure overloads
• Dry, oil-free measuring cell
• Available as an absolute or relative pressure sensor
• Easy set-up
• Materials: 1.4404/316L, ceramics
• CIP-/SIP capable 140°C / 30 min.
Flow Switches calorimetric / ultrasonic - HPQ Tech Vietnam Co.,Ltd
NEGELE flow switch will monitor your process reliable and cost-effective using the ultrasonic Doppler method or the calorimetric principle. The two sensors are mechanically and electrically interchangeable.

Only FDA-compliant materials come into contact with product.

Advantages:
Calorimetric Sensor
• Ideal for all aqueus (not oleiferous) media. Applicable for high-purity and fine filtered media.
• Built-in sensor protection
• 5 second response time
• Measurements up to 100°C
• No need to align sensor with flow direction
• Binary output
• CIP-/SIP capable

Ultrasonic sensor - HPQ Tech Vietnam Co.,Ltd
• Can be used with all media starting at 1 NTU turbidity and particle diameter > 50 μm (tap water, milk, CIP media, etc.)
• Unaffected by changes in temperature
• Lightning-fast response time < 1 s
• Measurements up to 140°C
• Binary or analog output
• CIP-/SIP capable
MAG-Flow-Meter (FMA) - HPQ Tech Vietnam Co.,Ltd
Very compact and variable flow meter, suitable for all fluids with a conductivity of >5 μS/cm.

Advantages: - HPQ Tech Vietnam Co.,Ltd
• Extreme compact dimensions
(most compact meter on the market)
• Housing completely made of stainless steel
• Highest variability in process connections and pipe standards
Process connections:
Welding connection, TriClamp, Dairy flange
DIN 11851; DIN 11864 hygienic thread connection,
APV flange, SMS and many more.
Custom specific connections on request!
Pipe standards:
DIN 11851 series 1 and 2; DIN 11866 series A, B
and C; OD-Tube; ISO 2037

• Highest safety against permeating humidity
To configure the meter it’s not necessary to open the housing; Configuration by magnet pen Protection type: IP69K


  For more information on Negele product visit their web site at: http://www.anderson-negele.com/en.html 

NEGELE Viet Nam Distributor
HPQ tự hào là đại lý phân phối độc quyền cảm biến NEGELE tại Việt Nam

Nguyễn Hoài Quyết
DĐ: 0938 400412
Email: hoaiquyet@hpqtech.com / nguyenhoaiquyet@gmail.com
Company name: HPQ Co.,Ltd
Address: 519/10 Road No.10, Ward 8, Go Vap District, HCMC, Viet Nam.
http://www.hpqtech.com
Tel: 08 6295 8401
Fax: 08 6295 8402

Không có nhận xét nào:

Đăng nhận xét